A field result becomes useful when it is produced consistently, connected to the event and interpreted within a clear operating rule.

Choose Your Equipment
The control loop

A four-stage operating method.

The exact test differs by product and application, but the evidence discipline remains the same.

01 • TEST

Use the defined method

Take the correct sample, use the correct equipment and follow the required handling procedure.

02 • RECORD

Capture the event

Link the result to the operator, fuel source, vehicle or tank, date, time and photographs.

03 • VERIFY

Apply the rule

Compare the observation with the expected range, correction guidance or acceptance criteria.

04 • ESCALATE

Protect the operation

Quarantine risk, retain evidence and obtain confirmatory analysis when required.

Before testing

Define the purpose and the sample point.

A result is only as useful as the sample and the question it is intended to answer. Testing fuel from an irrelevant or contaminated point can create false confidence or unnecessary alarm.

  • Identify the fuel grade and source
  • Choose a representative sampling point
  • Use clean, compatible sampling equipment
  • Record temperature where density is measured
  • Avoid cross-contamination between samples
  • Retain a reference sample when disputes are possible

Field screening is not laboratory certification

FuelGuard products are designed to support operational screening, early detection and evidence collection. Where legal, insurance, contractual or technical certainty is required, use an accredited laboratory and the appropriate chain-of-custody procedure.

Product-specific use

What each FuelGuard product contributes.

ProductPrimary purposeEvidence to retainTypical escalation
DensiTestRapid diesel integrity screening at a refuelling or custody-transfer event.Test photograph, event details, supplier, location, timestamp and observations.Stop or quarantine, retain sample and obtain confirmatory laboratory analysis.
Diesel hydrometer kitMeasure observed diesel density and fuel temperature.Hydrometer reading, temperature, correction reference, sample point and photograph.Repeat with a representative sample and confirm against specification or laboratory analysis.
Petrol hydrometer kitMeasure observed petrol density and temperature under safe controlled conditions.Reading, temperature, sample source, operator and safety record.Quarantine and escalate unusual results using the appropriate technical procedure.
AquaTrap™Support selected free-water control applications in compatible storage environments.Tank details, selected size, deployment date, inspection and replacement record.Investigate the source of water ingress and assess tank condition.
Safe field practice

Fuel handling requires disciplined safety controls.

Control ignition sources

Follow site rules for smoking, sparks, electrical equipment, static and open flames.

Work in ventilation

Avoid inhalation and perform petrol-related procedures only in a suitable ventilated environment.

Use appropriate PPE

Apply the site risk assessment, gloves, eye protection and spill-response requirements.

Manage samples correctly

Label, store, transport and dispose of fuel samples according to applicable requirements.

Follow the product guide

Use the correct range, fill volume, reading method and cleaning procedure.

Train the operator

Do not rely on equipment alone; verify competency and practical procedure adherence.

Choose the equipment, define the evidence and train the operator.

FuelGuard can help structure a practical SOP around the products and operating risk.